Error codes › Refrigerator
Refrigerator error codes
92 codes from 16 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Dometic CFX3 (1)
- ALERT VOLTAGE LOWCFX3 battery-protection lockout displayed on the TFT screen. The unit measured supply voltage below the…
Dometic CRX (Secop BD electronic unit) (5)
- 1 blink (Secop BD)Battery-protection cut-out. Supply voltage at the Secop electronic unit is below the cut-out threshold (or…
- 2 blinks (Secop BD)Fan over-current. The Secop electronic unit sensed more than 1.0 A on the F+/F- fan terminals. Identical…
- 3 blinks (Secop BD)Compressor start failure. The compressor motor could not reach the minimum start speed of approximately 1850…
- 4 blinks (Secop BD)Minimum compressor speed error. Compressor reached start RPM but immediately dropped below the minimum…
- 5 blinks (Secop BD)Thermal cut-out / electronic unit over-temperature. The Secop electronic unit sensed its own temperature…
Dometic RM1350 (3)
- E0No communication between eyebrow display module and rear power module — 4-conductor ribbon cable, connector…
- E1Hardware fault in the gas operation system (Dometic RM1350 Service Manual Section 10). NOTE: the thermistor /…
- E2Thermistor open / temperature sensor failure detected by the power module.
Everchill 10.7 (SRD-360WTG-E) (6)
- Light 1 flashingRefrigerator compartment temperature sensor fault.
- Light 2 flashingAmbient temperature sensor fault.
- Light 3 flashingFreezer defrosting sensor fault.
- Light 4 flashingUndervoltage alarm.
- Light 5 flashingOvervoltage alarm.
- Lights 1 & 3 flashingFan failure (freezer or condenser fan).
Everchill 16.2 (CCD-0007855) (9)
- UCCommunication failure or model mismatch — control board cannot talk to display panel.
- RSSensor failure (refrigerating chamber).
- CSSensor failure (drinks box).
- FSSensor failure (freezing chamber).
- FDDefrosting sensor failure.
- FFFan failure.
- ESFailure of ambient temperature sensor.
- LULow voltage alarm — DC supply below operating threshold.
- OUOver voltage alarm - DC supply above the controller's limit (the cited manual publishes no numeric…
Everchill BCD280 (4)
- Lights 1 & 2 flashingRefrigerator temp sensor in wind channel is not reading correctly or is unplugged
- Lights 2 & 3 flashingDefrost temp sensor not reading correctly or is unplugged
- Lights 3 & 4 flashingFreezer fan fault
- All 5 lights flashingUnder-voltage or over-voltage has occurred on the DC input
Everchill SRD-360W TG-E (10.7 cu ft) (4)
- Temp Control 1+2 flashingRefrigerator wind-channel temp sensor fault — sensor unplugged at CN2 on main PCB or sensor failed
- Temp Control 2+3 flashingDefrost temp sensor not reading or unplugged
- Temp Control 3+4 flashingFreezer fan fault - no 12 V at the freezer fan or fan seized/failed
- All four Temp Control LEDs flashingUnder/over voltage detected — supply outside operating range
Furrion FCR Arctic 8/10 (6)
- 1 flashVoltage Fault — input voltage to compressor inverter is outside normal parameters.
- 2 flashesFan Fault Current — fan output current exceeds 1 A peak.
- 3 flashesCompressor Start Fault — rotor blocked or system pressure too high (>6 bar).
- 4 flashesMinimum Motor Speed Error — compressor motor cannot maintain minimum 1850 RPM under load.
- 5 flashesThermal Fault — system shut down due to high temperature (ambient or working too hard).
- 6 flashesController Hardware Fault — driver board detects abnormal internal parameters.
Furrion FCR Arctic French Door (FCR20DCAFA-SV) (1)
- FF ERFreezer fan fault. Reported by the appliance when the freezer circulation fan - the fan that moves cold air…
GE GPV10 (1)
- (no display)The GE GPV10 has NO electronic fault-code display - diagnosis is conducted with a multimeter at well-defined…
Norcold 1210T (13)
- dc LODC voltage below 10.5 V at the power board for >25 seconds
- dc HIDC voltage above 15.4 V at the power board for >25 seconds
- no ACAC mode selected but input voltage below 85 V for >25 seconds
- no FLBurner failed to light or relight within the 30-second trial-for-ignition window
- L1 oPHigh-temperature limit switch open — boiler exceeded 378 °F
- FL --Flame sensed at burner when gas is supposed to be off
- drDoor sensed ajar or open for more than 2 minutes
- Blank displayNo display segments, refrigerator does not turn on
- Flashing temp setting (thermistor)Temperature setting flashes — thermistor disconnected/open OR thermistor wiring corroded/broken.
- Alternating display + alarm (extended)Alternating display + alarm pattern from the 1210T power board. Three documented causes share this same…
- AC HEAC heaters failed open — recorded in AUTO or Manual AC mode when AC-heater current input falls below 0.5 A…
- AC rEAC relay stuck closed — AC heater current is sensed when it is supposed to be off (recorded in all modes ~25…
- SrFlame sensing malfunction — recorded in all modes when: (1) a problem in the flame-sense circuitry; (2) the…
Norcold N15DCX/N20DCX (1520cu) (15)
- 1 flash (compressor self-test)Compressor Power Module Battery Protection Cut-Out. The DC voltage at the compressor power module is outside…
- 2 flashes (compressor self-test)Fan Over Current Cut-Out. The compressor power module sensed more than 1.0 amp on terminal F-. (Source…
- 3 flashes (compressor self-test)Compressor Motor Start Error. The rotor is blocked or the differential pressure in the refrigeration system…
- 4 flashes (compressor self-test)Minimum Compressor Motor Speed Error. The motor cannot maintain the minimum speed of 1850 rpm. (Source…
- 5 flashes (compressor self-test)Thermal Cut-Out of Compressor Power Module. The compressor power module circuit board temperature is above…
- 6 flashes (compressor self-test)Compressor Power Module Hardware Failure. (Source manual: Test K, with associated cross-check that voltage is…
- E1Fresh food compartment thermistor not cycling properly. The fresh-food thermistor signal is open, shorted, or…
- E2Freezer compartment thermistor not cycling properly. Same logic as E1 but for the freezer thermistor.
- E3Voltage outside the cut-out setting. The user-interface cut-out range is 10.4-15.6 VDC ±0.2; startup must be…
- E4Fresh food compartment door has been open for more than 2 minutes. Either the door is genuinely open or a…
- E5Voltage too low. Distinct from E3 in that E5 indicates voltage below the 11.9 VDC startup threshold…
- E6Ambient thermistor not cycling properly. Same logic as E1/E2 but for the ambient (Item L) thermistor on top…
- E7Evaporator fan not operating properly. The fresh-food evaporator fan (Item N in source wiring diagram) is…
- E8Freezer condenser fan not operating properly. The freezer condenser fan (Item P in source wiring diagram) is…
- E9Fresh food condenser fan not operating properly. The fresh-food condenser fan (Item O in source wiring…
Norcold N6XX/N8XX (14)
- F / no FLBurner failed to ignite or reignite — flame sensing circuit did not detect flame within the 30-second…
- S / SrFlame sense circuit failure detected by the power board. Applies to N62X/N82X and N64X/N84X models. Distinct…
- dc LODC voltage low — power board sees input below 10.5 VDC. Common false-positive cause: AC ripple from an older…
- dc HIDC voltage high — power board sees input above 15.4 VDC. Most often caused by AC ripple from a converter, not…
- dc rEDC relay stuck closed (N64X.3/N84X.3 3-way models only). Power board detects the DC heater relay K3 is not…
- dc HEDC heater failed open (N64X.3/N84X.3 3-way models only). Power board detects open circuit in the 3-way DC…
- A / no ACNo AC power available to the refrigerator. Controls cannot start AUTO AC or AC-Manual mode. In AUTO, controls…
- H / AC rEAC relay stuck closed. Power board detects the AC heater relay K2 is not opening when commanded — the heater…
- AC HIAC voltage high — power board measured above 132 VAC at the AC input.
- AC LOAC voltage low — power board measured below 108 VAC at the AC input.
- P / AC HEAC heater failed open. Power board detects open circuit in the 120 VAC heater element. Appears as AC-mode 'no…
- d / drFresh food compartment door reported open for more than 2 minutes. Detected by door switches; per the 121X…
- n / no coNo cooling detected by the controls. Power board monitors cooling-system temperature drop during operation…
- 10 sec flashesThe refrigerator has fallen back to its Back Up Operating System. Per the manual this happens when the…
Vitrifrigo (Secop BD electronic unit) (5)
- 1 blink (Secop BD)Battery-protection cut-out. Supply voltage at the Secop electronic unit is below the cut-out threshold (~10.5…
- 2 blinks (Secop BD)Fan over-current. The Secop electronic unit sensed more than 1.0 A on the F+/F- fan terminals. Identical…
- 3 blinks (Secop BD)Compressor start failure. Motor could not reach the minimum start speed of approximately 1850 rpm within the…
- 4 blinks (Secop BD)Minimum compressor speed error. Compressor reached start RPM but immediately dropped below the minimum…
- 5 blinks (Secop BD)Thermal cut-out / electronic unit over-temperature. The Secop electronic unit sensed its own temperature…
Whynter (1)
- Lo VoltWhynter low-voltage battery-protection cut-out. On the FM-series (12 V) the unit stops running below ~10.4 V…
Whynter (Secop BD electronic unit) (4)
- 1 blink (Secop BD)Battery-protection cut-out on Whynter FM/BCD models with the Secop electronic unit. Identical chart to…
- 2 blinks (Secop BD)Fan over-current. Secop electronic unit sensed >1.0 A on F+/F- terminals. Same diagnosis as Norcold DCX…
- 3 blinks (Secop BD)Compressor start failure on Whynter Secop-platform models. Motor could not reach minimum start speed. Same…
- 5 blinks (Secop BD)Thermal cut-out / electronic unit over-temperature. Always an environmental issue.