Error codes › Refrigerator › ICECO (Secop BD) › E4

ICECO (Secop BD) error code E4

FaultRefrigeratorVerified against the manufacturer's manual

Minimum motor speed error: the compressor is overloaded and cannot hold its minimum speed of 1850 rpm. Same as Secop BD error 4 (Speed failure); Secop's speed limits are 1850 rpm minimum, 3750 rpm maximum.

What to check, and in what order, is in the app. The flow ICECO portable fridge - E1-E7 / LL / HH display code (Secop compressor) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Refrigerator error codes · Look up another code