ICECO (Secop BD) error code E4
Minimum motor speed error: the compressor is overloaded and cannot hold its minimum speed of 1850 rpm. Same as Secop BD error 4 (Speed failure); Secop's speed limits are 1850 rpm minimum, 3750 rpm maximum.
What to check, and in what order, is in the app. The flow ICECO portable fridge - E1-E7 / LL / HH display code (Secop compressor) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- ICECO VL35/45/60 ProS User Manual V7.0ICECO
- Secop BD Controllers Operating Instructions (101N0212-650)Secop
Related codes
- E1Battery protection: the DC input voltage is below the…
- E2Cooling (condenser) fan over-current: the fan is drawing more than 1…
- E3Compressor motor start error: repeated on/off switching, a faulty…
- E5Compressor control module (ECU) temperature protection: the module is…
- E6/LLTemperature sensor (sensing head) loose or damaged. This meaning is…
- E7/HHNTC temperature-sensor short circuit. This meaning is from the VL…