ICECO (Secop BD) error code E7/HH
NTC temperature-sensor short circuit. This meaning is from the VL ProS / VL ProD / VL45 / GO20 / JP ProS / JP ProD / APL20 / APL55 / VL45 Plus manuals. NOT the same on the APL35: there E7/HH is a display-panel to control-board communication failure. Do not read this ICECO E7 as Secop error 7 (Communication error).
What to check, and in what order, is in the app. The flow ICECO portable fridge - E1-E7 / LL / HH display code (Secop compressor) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- ICECO VL35/45/60 ProS User Manual V7.0ICECO