ICECO (Secop BD) error code E7/HH

FaultRefrigeratorVerified against the manufacturer's manual

NTC temperature-sensor short circuit. This meaning is from the VL ProS / VL ProD / VL45 / GO20 / JP ProS / JP ProD / APL20 / APL55 / VL45 Plus manuals. NOT the same on the APL35: there E7/HH is a display-panel to control-board communication failure. Do not read this ICECO E7 as Secop error 7 (Communication error).

What to check, and in what order, is in the app. The flow ICECO portable fridge - E1-E7 / LL / HH display code (Secop compressor) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Refrigerator error codes · Look up another code