ICECO (Secop BD) error code E2
Cooling (condenser) fan over-current: the fan is drawing more than 1 A. Same as Secop BD error 2 (Fan failure).
What to check, and in what order, is in the app. The flow ICECO portable fridge - E1-E7 / LL / HH display code (Secop compressor) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- ICECO VL35/45/60 ProS User Manual V7.0ICECO
- Secop BD Controllers Operating Instructions (101N0212-650)Secop
Related codes
- E1Battery protection: the DC input voltage is below the…
- E3Compressor motor start error: repeated on/off switching, a faulty…
- E4Minimum motor speed error: the compressor is overloaded and cannot…
- E5Compressor control module (ECU) temperature protection: the module is…
- E6/LLTemperature sensor (sensing head) loose or damaged. This meaning is…