Error codes › Generator
Generator error codes
105 codes from 8 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Cummins Onan (3)
- 58 (Exhaust Gas Temperature Shutdown)Exhaust gas temperature reached 650C (1202F) for 2 seconds while the set was running. See an authorized Onan…
- 81 (EGT Sensor Open)Exhaust Gas Temperature sensor stuck open (open circuit). Authorized dealer service required.
- 82 (EGT Sensor Shorted)Short circuit in the Exhaust Gas Temperature sensor. Authorized dealer service required.
Cummins-Onan EC-30W (5)
- Failed to StartEC-30W commanded genset to start, but genset did not start after three crank attempts. AGS disables.
- Failed to StopEC-30W commanded genset to stop, but genset continued running. AGS disables.
- Motion FaultAccelerometer diagnostics failed. AGS is disabled.
- Display BatteryDisplay battery voltage too low for AGS operation. Genset stops and AGS disables.
- Verify MotionEC-30W has not detected any motion in last 30 days. AGS disables.
Cummins-Onan KY (19)
- 3 (KY)Service Check fault (first-level code) - it indicates a second-level fault code; press STOP once to display it
- 4 (KY)Overcrank — cranked >20 sec without start
- 13 (KY)Undervoltage - the controller is unable to maintain rated output voltage.
- 14 (KY)Overfrequency - the engine governor is unable to maintain rated frequency.
- 15 (KY)Underfrequency - the engine governor is unable to maintain rated frequency.
- 29 (KY)Battery voltage >19 V
- 12 (KY)Over Voltage — the control is unable to maintain rated output voltage.
- 27 (KY)Voltage Sense — the control is unable to sense output voltage.
- 32 (KY)Low Cranking Speed — cranking speed is less than 180 RPM for more than 2 seconds.
- 35 (KY)Control Card Failure — a microprocessor EEPROM error occurred during self-test.
- 36 (KY)Engine Stopped — the engine stopped without receiving a command from the control.
- 37 (KY)Invalid Generator Set Configuration - the genset configuration is preprogrammed at the factory; an invalid…
- 38 (KY)Over Current (Field Overload) — low power-factor loads.
- 41 (KY)Generator Rotor — the control is unable to sense field or output voltage.
- 42 (KY)Processor — a microprocessor ROM error occurred during self-test.
- 43 (KY)Processor — a microprocessor RAM error occurred during self-test.
- 45 (KY)Speed Sense — the control is unable to sense quadrature frequency.
- 47 (KY)Ignition — the control is unable to sense ignition.
- 48 (KY)Generator Field Sense — the control is unable to sense field voltage.
Cummins-Onan QD (23)
- 3 (QD)Service check — a second-level fault is stored. Press Stop once to make the status lamp blink the two-digit…
- 4 (QD)Overcrank — generator failed to start within the cranking time allowed. (4 amber blinks)
- 12 (QD)Over-voltage — automatic shutdown (after voltage regulation was enabled, output rose above 150 VAC [125% of…
- 13 (QD)Under-voltage — automatic shutdown (after voltage regulation was enabled, output fell below 108 VAC [90% of…
- 14 (QD)Over-frequency — automatic shutdown (after the starter engaged, frequency rose above 70 Hz for 40 ms, or…
- 15 (QD)Under-frequency — automatic shutdown (during normal operation, frequency fell below 54 Hz for more than 8 s).…
- 19 (QD)Actuator shorted or open — at startup the controller sensed an open or shorted governor actuator or harness.…
- 22 (QD)Actuator overload — the controller held the governor actuator at full duty cycle (maximum PWM) for 60 s…
- 24 (QD)Faulty engine temperature sender — after 10 minutes of normal operation the controller sensed an open…
- 27 (QD)VAC sense lost — the controller lost AC-voltage sensing during normal voltage regulation while the field was…
- 29 (QD)High battery voltage — the controller sensed battery-system voltage greater than 19.2 V (at startup, or for 1…
- 32 (QD)Starting fault — the controller could not detect cranking speed (quadrature zero crossings) for 12 s. (Code…
- 35 (QD)EE checksum fault — at startup the controller detected an EEPROM memory error. (Code 35, second-level)
- 36 (QD)Mechanical fault — engine speed fell below 1000 RPM for 0.5 s (not by controller action). (Code 36…
- 38 (QD)Field overload — during normal voltage regulation, field voltage exceeded 180 VAC for 10 s. (Code 38…
- 41 (QD)Generator rotor short — while flashing the field the controller sensed the rotor circuit shorted to ground.…
- 42 (QD)ROM fault — at startup the controller detected a ROM memory error. (Code 42, second-level)
- 43 (QD)RAM fault — at startup the controller detected a RAM memory error. (Code 43, second-level)
- 45 (QD)Speed sense lost — after start disconnect the controller lost speed sense (quadrature zero crossings) for…
- 48 (QD)Loss of field sense — the field-sense circuit on the controller board failed during normal voltage…
- 57 (QD)Overprime — the local or remote control switch was held in the PRIME (Stop) position for more than 3 minutes.…
- 1 (QD)High engine temperature — automatic shutdown (engine coolant temperature exceeded 239 °F / 115 °C for 10 s).…
- 2 (QD)Low oil pressure — automatic shutdown (engine oil pressure dropped to less than 14 psi for 3 s, oil-pressure…
Onan HGJAA-HGJAF (27)
- 1 blinkFirst-level shutdown: high engine coolant temperature (where equipped).
- 2 (Low Oil Pressure)First-level fault. Low-oil-pressure cutoff switch did not open (switch grounded at controller P1-6).…
- 3 (Service Check)First-level fault indicating a two-digit fault code is logged. While LED is flashing 3x, press STOP once to…
- 4 (Overcrank)First-level fault. Cranking exceeded 30 seconds without engine starting. Controller cannot sense generator…
- 12 (Overvoltage)Controller unable to maintain rated voltage. Instantaneous: AC S1-S2 >150 VAC. Delayed: 138-150 VAC for 3…
- 13 (Undervoltage)Controller unable to maintain rated voltage. AC S1-S2 below 108 VAC for 5 continuous seconds.
- 14 (Overfrequency)Instantaneous: freq >70 Hz (60 Hz set) or >58 Hz (50 Hz set). Delayed: 66-70 Hz for 6 sec (60 Hz) or 55-58 Hz…
- 15 (Underfrequency)Engine governor unable to maintain rated frequency. 60 Hz carburetor models: <54 Hz for 30 continuous…
- 17 (Fuel Pump Fault)Pre-2001 models only. Controller detected an OPEN fuel pump circuit at the control (the manual's FC 17 logic…
- 23 (Oil Pressure Switch Fault)Pre-2001 models only. Continuous open on oil pressure switch input before cranking (not a running fault).…
- 27 (Voltage Sense Lost)Controller unable to sense output voltage (sense lead open, blown sense fuse, or field collapse). Manual…
- 29 (High Battery Voltage)Voltage across battery system greater than 19 VDC.
- 32 (Low Cranking Speed)Cranking too slow: quadrature frequency ≤3 Hz AND engine RPM ≤100 RPM for 12 continuous seconds after…
- 33NOT ASSIGNED. If seeing blink pattern that looks like 33, it is actually first-level code 3 (Service Check) …
- 35 (Control Card Failure)Microprocessor EEPROM error during self-test.
- 36 (Engine Stopped Without Fault)Engine stopped without command by controller. Manual logic: RPM less than 500 AND sense voltage S1-S2 at 0…
- 37 (Invalid Configuration)Wrong frequency/RPM ratio detected (configuration mismatch).
- 38 (Field Overload / Overcurrent)Field voltage F1-F2 greater than 150 VDC for 10 continuous seconds.
- 41 (Alternator/Generator Rotor Fault)Post-2003 models only. Field voltage F1-F2 = 0 VDC AND sense voltage S1-S2 = 0 VAC for 1 continuous second…
- 42 (Processor Fault - ROM)Microprocessor ROM error during self-test.
- 43 (Processor Fault - RAM)Microprocessor RAM error during self-test.
- 44NOT ASSIGNED. If seeing blink pattern that looks like 44, it is actually first-level code 4 (Overcrank).
- 45 (Speed Sense Fault)Controller unable to sense quadrature frequency (Q1-Q2 signal lost; the Q1-Q2 winding generates the…
- 47 (Ignition Fault)Controller unable to sense ignition pulses (used for RPM input). On HGJAB and HGJAE the fault is enabled only…
- 48 (Field Sense Fault)Controller unable to sense field voltage.
- 51 (Processor Failure)Microprocessor malfunction.
- 57 (Overprime Fault)Prime mode (STOP/PRIME held) exceeded 3 minutes.
Onan HGJAA-HGJAF (EFI) (5)
- 19 (Governor Actuator Fault)EFI only. Controller sensed open or shorted circuit in throttle body/governor actuator.
- 22 (Governor Actuator Overload)Pre-2001 EFI models only. Maximum governor output (PWM) sustained for 10 continuous seconds (operation at or…
- 52 (Fuel Injector Fault)EFI only. Open or short circuit in fuel injector.
- 54 (MAT Sensor Fault)EFI only. Open or short circuit in MAT sender. Manual threshold: MAT sender input greater than 300k Ohms.
- 56 (MAP Sensor Fault)EFI only. Open or short circuit in MAP sender. Manual threshold: MAP sensor input less than 50 kPa at start.
Onan HGJAA-HGJAF (HGJAD/E/F) (1)
- 31 (Overspeed)Overspeed (per source manual ch.12.25, only triggered in ERO/Engine Run Only mode): 5 kW sets >2880 RPM via…
Xantrex AGS (22)
- Gen Won't StartGenerator failed to start after four attempted cranking cycles over 12-minute period
- Gen Quiet FaultAutomatic generator start condition met during programmed quiet-time window; alerts user that generator will…
- Low AC Input VAC input voltage drops below 45 VAC (Power Tech generators only); indicates weak generator output or…
- W200Generator was stopped manually.
- W201Generator was started manually.
- W202Unable to start generator. AGS will try again.
- W203Manual Off: Max generator run time reached. Reset AGS Mode.
- W204Manual Off: Max generator cycles reached. Reset AGS Mode.
- W205Generator started by its switch. Use its switch to stop.
- W206Mismatched triggers. Enable stop trigger or disable start trigger.
- W207Mismatched triggers. Enable start trigger or disable stop trigger.
- W208Auto triggers not enabled. Config auto triggers
- W209Gen external stop. Start gen via its control panel.
- W250The selected value failed to change. Try again.
- W500Network connection lost. Check connections.
- W501AGS has fixed memory problem and restored default settings.
- F200Exceeded max number of start tries. Check gen, clear fault.
- F201Unable to stop gen. Stop gen via its control panel.
- F203Manual Off: Gen stopped by ext sensor. Reset AGS mode.
- F500Serial Number Failure, Service Required.
- F501Memory Failure. Service Required.
- F505Internal Failure. No Service Required. A controller fault has occurred and the Auto Gen Start has gone into…