Error codes › Generator › Cummins-Onan QG i › 26 (QG 2800i/2500i)

Cummins-Onan QG i error code 26 (QG 2800i/2500i)

FaultGeneratorVerified against the manufacturer's manual

Alternator Under Voltage. Permanent Magnet Alternator (PMA) output voltage is out of range low. The generator set will shut down. QG 2800i / 2500i LP (HGLAA) code table - NOT the HGJAA (0983-0501) or KY table; the same number carries a different meaning on those families and on the QG i DF family (see the '(QG i DF)' entries). All HGLAA fault codes shut the generator set down; the status indicator light in the control switch flashes the code.

What to check, and in what order, is in the app. A step-by-step flow walks this code with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Generator error codes · Look up another code