Cummins-Onan QG i error code 14 (QG i DF)
Over Frequency. Indicates the engine governor is unable to maintain rated frequency. Service manual logic: output frequency more than 63 Hz - AC output is cut, engine keeps running; listed cause is the inverter. QG i DF dual-fuel family (QG 7000i DF = HGLCA, QG 4000i DF = HGLDA, QG 2800i DF = HGLEA) code table - distinct from the QG 2800i/2500i (HGLAA) table and from the HGJAA (0983-0501) and KY tables. The status indicator flashes a 1-digit code, or two sets of flashes (tens, pause, units) for a 2-digit code; flashing stops after 5 minutes and pressing STOP/PRIME 3 times within 5 seconds resumes it. The last fault logged keeps flashing after the condition is corrected.
What to check, and in what order, is in the app. A step-by-step flow walks this code with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Operator Manual RV Generator Set HGLCA Spec A (QG 7000i DF), A079E225 Issue 1Cummins Onan
- Operator Manual RV Generator Set HGLDA Spec A (QG 4000i DF), A080H582 Issue 1Cummins Onan
- Operator Manual RV Generator Set HGLEA Spec A (QG 2800i DF), A080H579 Issue 1Cummins Onan
- Service Manual RV Generator Set HGLCA Spec A (QG 7000i DF), A079E227 Issue 1Cummins Onan
Related codes
- 4 (QG i DF)Over Crank. indicates that cranking exceeded 15 seconds without the…
- 6 (QG i DF)Low Oil Pressure. Indicates that the low oil pressure cutoff switch…
- 12 (QG i DF)Over Voltage. Indicates the control is unable to maintain rated…
- 13 (QG i DF)Under Voltage. Indicates the control is unable to maintain rated…
- 15 (QG i DF)Under Frequency. Indicates the engine governor is unable to maintain…
- 19 (QG i DF)Actuator Circuit Fault. Indicates TPS and all the step motor open or…
- 25 (QG i DF)Alternator Overvoltage. Indicates that the inverter bus voltage 250V…
- 26 (QG i DF)Alternator Undervoltage. Indicates that the inverter bus voltage…