Onan HGJAA-HGJAF error code 14 (Overfrequency)
Instantaneous: freq >70 Hz (60 Hz set) or >58 Hz (50 Hz set). Delayed: 66-70 Hz for 6 sec (60 Hz) or 55-58 Hz for 6 sec (50 Hz).
What to check, and in what order, is in the app. The flow Onan Code 14 — Overfrequency walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Cummins-Onan Service Manual (document 0983-0501 Issue 26, March 2018, 202 pp) covering HGJAA Spec A-E / HGJAB A-E / HGJAC A-C / HGJAD A-E / HGJAE A-E / HGJAF A-C (rv-tech-resources/25-onan-hgjaa/0983-0501_Onan_HGJAA-HGJAF_Service_Manual_Issue_26.pdf)
- Onan HGJAA Generator Technician Service Diagnostic Reference (rv-tech-resources/25-onan-hgjaa/Onan_HGJAA_Generator_Technician_Service_Diagnostic_Reference.md)
Related codes
- 3 (Service Check)First-level fault indicating a two-digit fault code is logged. While…
- 4 (Overcrank)First-level fault. Cranking exceeded 30 seconds without engine…
- 12 (Overvoltage)Controller unable to maintain rated voltage. Instantaneous: AC S1-S2…
- 13 (Undervoltage)Controller unable to maintain rated voltage. AC S1-S2 below 108 VAC…
- 15 (Underfrequency)Engine governor unable to maintain rated frequency. 60 Hz carburetor…
- 17 (Fuel Pump Fault)Pre-2001 models only. Controller detected an OPEN fuel pump circuit…
- 23 (Oil Pressure Switch Fault)Pre-2001 models only. Continuous open on oil pressure switch input…
- 27 (Voltage Sense Lost)Controller unable to sense output voltage (sense lead open, blown…