Cummins-Onan QG i error code 73 (QG i DF)
AC Output Circuit Fault. Indicates that a short circuit of the AC output to ground is detected. Service logic: hot-to-hot or hot-to-neutral short; output is cut, engine keeps running. Disconnect the load and test it for a short, test the output wiring, then inverter. QG i DF dual-fuel family (QG 7000i DF = HGLCA, QG 4000i DF = HGLDA, QG 2800i DF = HGLEA) code table - distinct from the QG 2800i/2500i (HGLAA) table and from the HGJAA (0983-0501) and KY tables. The status indicator flashes a 1-digit code, or two sets of flashes (tens, pause, units) for a 2-digit code; flashing stops after 5 minutes and pressing STOP/PRIME 3 times within 5 seconds resumes it. The last fault logged keeps flashing after the condition is corrected.
What to check, and in what order, is in the app. A step-by-step flow walks this code with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Operator Manual RV Generator Set HGLCA Spec A (QG 7000i DF), A079E225 Issue 1Cummins Onan
- Operator Manual RV Generator Set HGLDA Spec A (QG 4000i DF), A080H582 Issue 1Cummins Onan
- Operator Manual RV Generator Set HGLEA Spec A (QG 2800i DF), A080H579 Issue 1Cummins Onan
- Service Manual RV Generator Set HGLCA Spec A (QG 7000i DF), A079E227 Issue 1Cummins Onan
Related codes
- 52 (QG i DF)Fuel Injector or IPM Pump Circuit Fault. Indicates that there is an…
- 53 (QG i DF)Oil Temperature Sensor Circuit Fault. Indicates that an open or short…
- 54 (QG i DF)MAT Sender. Indicates that there is an open or short circuit in the…
- 57 (QG i DF)Over Prime Or LPG Pressure Sensor Fault, The LPG Solenoid Valve…
- 81 (QG i DF)Alternator Stator Circuit Fault. Indicates that the internal of…
- 85 (QG i DF)Oxygen Sensor Fault. Indicates that the oxygen sensor is not working…