RV Safe error code Red LED on/flashing + 4 chirps then constant beeps, right after pressing Silence/Test
Self Test PASSED: pressing Silence/Test in normal operation tests the CO sensor, propane sensor and battery voltage. REV 06.01.22: 2 cycles of the CO horn pattern (4 rapid chirps followed by a 4 second pause) followed by the propane horn pattern (constantly beeping). REV 12.05.19: 2 cycles of the CO pattern followed by 2 cycles of the propane pattern. Green LED off, red LED on/flashing during the test. The test exercises electrical functions only, not the alarm's ability to detect gases.
What to check, and in what order, is in the app. The flow RV Safe RVCOLP / RVLP - alarm, LED and self-test signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- RV Safe CO & Propane Gas Alarm RVCOLP-2 / Propane Gas Alarm RVLP-2 Owner's Manual, REV 06.01.22 (90-5012-20)RV Safe LLC
- RV Safe CO & Propane Gas Alarm RVCOLP-2 / RVCOLP-3 and Propane Gas Alarm RVLP-2 / RVLP-3 Owner's Manual, REV 12.05.19 (90-4074-00)RV Safe LLC
Related codes
- Green LED on, red LED off, no soundNormal operation: the alarm is functioning normally and no CO or…
- No LEDs lit, no soundPower Off state: the alarm has no 12 VDC supply. Both manuals: if no…
- Green LED flashing, red off, no sound (first 3 minutes after power-up)Warm-Up state (REV 06.01.22 manual only): the green LED flashes for…
- Red LED flashing + 4 rapid chirps, 4 s pause, repeatingCO ALARM (RVCOLP models only): CO exceeded the detection threshold…
- Red LED on + constant beepsPROPANE ALARM: propane at the sensor exceeded the alarm threshold for…
- Red LED flashing once each second, no soundAlarm Silenced state: Silence/Test was pressed during a CO or propane…
- Both LEDs flash once each minute + 1 chirp each minuteLOW BATTERY state: the 12 VDC supply has dropped below the…