RV Safe error code Both LEDs flash once each minute + 1 chirp each minute

WarningLP / Propane SystemVerified against the manufacturer's manual

LOW BATTERY state: the 12 VDC supply has dropped below the low-battery threshold - REV 06.01.22: below 9 VDC; REV 12.05.19: below 8 VDC. The horn chirps every minute and both LEDs flash every minute. Alarm performance cannot be guaranteed below the threshold. This is a supply fault, not a detector fault. Two official revisions are archived and disagree; both values are stated. REV 06.01.22 = rvsafealarm.com copy (RVCOLP-2 / RVLP-2); REV 12.05.19 = Forest River copy (adds the 3-wire RVCOLP-3 / RVLP-3).

What to check, and in what order, is in the app. The flow RV Safe RVCOLP / RVLP - alarm, LED and self-test signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.