Southwire Surge Guard (portable LCD) error code L1 HIGH / L2 HIGH (WAS xxxV)
High voltage: the line voltage went above 136 V and the unit turned RV power off. 'WAS xxxV' records the voltage it saw (the manual's example is 'L1 HIGH WAS 137V'); L2 appears on the 50A models only. Once the voltage is back inside 102-136 V the unit runs DELAY and restores power after 128 seconds. Trip time: the spec tables in both operating manuals say 7 seconds; troubleshooting guide 506-00022A says below 102 VAC for more than 7 seconds and above 136 VAC for more than 8 seconds. CONFLICT (logged): both operating manuals (505-00152A and 505-00170A) and page 1 of troubleshooting guide 506-00022A give 102 / 136 VAC. Southwire's training manual lists the full-feature portables as Low (<102V) / High (>132V), and the error table on page 2 of 506-00022A prints the limits reversed ('lower voltage to >132V', 'raise voltage to <102V'). The suite uses the operating-manual figures, 102 / 136 VAC.
What to check, and in what order, is in the app. The flow Southwire Surge Guard portable - LCD message to cause (pedestal, coach or unit) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Surge Guard Installation & Operating Instructions, Models 34931 / 34951 (30A / 50A Portable, wireless)Southwire Company, LLC
- Surge Guard Troubleshooting Guide, Model 34930 (30A Portable with LCD Display)Southwire Company, LLC
- Surge Guard RV Power Protection Training ManualSouthwire Company, LLC
Related codes
- DELAYStart-up / restore countdown, not a fault. The LCD shows 'DELAY' and…
- REPLACE SURGESurge expended. The built-in surge protection has been sacrificed to…
- OPEN GROUNDOpen ground on the incoming power. The Surge Guard will not pass…
- REVERSE POLARITYL1 or L2 wired to neutral or ground (a miswired source), shown with…
- L1 LOW / L2 LOW (WAS xxV)Low voltage: the line voltage dropped below 102 V and the unit turned…
- NEUTRIP WAS xxAHigh neutral current trip (50A models 34950 / 34951 only - the spec…
- L1 AMPS WAS xxAOver-current: the current drawn through the Surge Guard exceeded the…
- RECEPT OVERHEATOverheating plug/receptacle: the Surge Guard's receptacle temperature…