Error codes › Solar
Solar error codes
120 codes from 10 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Furrion MPPT / Renogy (1)
- Solid redFault - typically wiring (reversed polarity), battery isolated, or short on output
Furrion MPPT solar controller (2)
- Solid greenBattery fully charged or in float charge stage (active charging = FLASHING green, not solid green)
- Flashing greenMPPT actively charging the battery (bulk / absorption charging)
Go Power (18)
- Solar Panel Reverse ConnectionSolar panel reverse polarity (- wire on the + post / in-line connector reversed). The GP-PWM-30-SQ shows…
- Solar Panel Over-Voltage (>26.5 V)Solar panel open-circuit voltage above 26.5 V at the controller input (LCD 'Solar panel over voltage (>…
- Solar Panel Weak / AbnormalSolar panel weak / low PV power (LCD 'Solar panel weak', flashing LED, LCD backlight ON). Normal at night; in…
- Battery Disconnected (<3.0 V)Battery disconnected or below 3.0 V at the battery input (LCD 'Battery disconnected or less than 3.0V'…
- Battery Reverse ConnectionBattery reverse polarity (red/black swapped at the controller's battery terminals). LCD 'Battery reverse…
- Battery Over-Voltage (>17.5 V)Battery-input voltage above 17.5 V (LCD 'Battery over voltage than > 17.5V', flashing LED) - typically…
- 32Controller cannot detect a battery — 5-pulse wake-up sequence failed (LiFePO4 BMS in deep-discharge or…
- 31Reported by the controller as the named status 'Charge Temperature Limits Violation' (not a numbered fault…
- E1Battery over-discharge -- output/charging cut to protect an over-discharged battery
- E2System over-voltage -- battery-bank voltage above the safe upper limit
- E3Battery under-voltage warning -- battery voltage below the controller's threshold
- E4Load short circuit on the controller's LOAD output
- E5Load overloaded -- LOAD-terminal draw exceeds the controller's rating
- E6Over-temperature inside controller -- internal/heatsink temperature too high
- E7Photovoltaic component overloaded -- PV input exceeds the controller's power rating
- E8Photovoltaic component over-voltage -- PV input above the controller's maximum voltage
- E9Photovoltaic component reversely connected -- solar + / - reversed at the PV input
- Battery Over-Temperature (>65 C)Battery temperature above 65 degC (LCD 'Battery temperature over 65C', flashing LED). Charging is inhibited…
Jaboni (5)
- High battery voltageThe battery bank is receiving charge from another controller (parallel charging source), or a battery cable…
- Low battery voltageThe battery bank is discharged, or one or more batteries are damaged. After clearing the cause, press the…
- High temperaturePoor ventilation around the unit, high ambient temperature, or continuous overload current (controller…
- High output currentA load was connected suddenly to the battery bank, or there is a short circuit at the output. After clearing…
- High solar panel voltageThe solar array (PV) voltage is higher than the charger limit (45 VDC max array; use an array rated for 12…
Renogy Rover (9)
- E0No error detected - the Rover is operating normally.
- E1Battery over-discharged - the controller's low-voltage disconnect (LVD) has cut the load to protect the…
- E2Battery over-voltage - battery voltage is above the safe limit; charging is suspended until it drops.
- E3Battery under-voltage - battery voltage is below the configured threshold.
- E4Load short circuit - the load output is shorted; the controller has disconnected the load.
- E5Load overloaded - load current exceeded 1.05x the rating; the controller disconnected the load.
- E6Controller over-temperature - the heat-sink temperature is too high. The Rover reduces charge current above…
- E8PV input over-current - solar input current exceeds the limit; charging current is limited to the rating.
- E10PV over-voltage - PV input voltage exceeds the 100 VDC maximum; PV stays disconnected until it drops below…
Rich Solar RS-MPPT50P (7)
- P-01Solar panel reverse connection — PV leads polarity-swapped at controller
- P-02Solar panel over-voltage (PV Voc > 95 V)
- b-01Solar panel is connected but battery is disconnected (or battery connection lost)
- b-02Battery reverse connection
- b-03Battery over-voltage (>17 V on a 12 V system)
- b-04Battery temperature over 65°C (via battery temperature sensor)
- OTPController over-temperature protection — charging current de-rates automatically
Rich Solar RS-PWM30P (9)
- E0No error — normal operating display
- E1Battery over-discharge — voltage fell below low-voltage disconnect threshold
- E2Battery over-voltage
- E3Under-voltage warning (approaching over-discharge threshold)
- E4Load short circuit
- E5Load overload — exceeds 30 A rated load current
- E6Temperature too high inside controller
- E8Charging current too high — exceeds 30 A
- E10Solar panel input voltage too high
Victron Multi RS Solar (53)
- 2Battery voltage too high
- 3Remote temperature sensor failure
- 4Remote temperature sensor failure
- 5Remote temperature sensor failure (connection lost)
- 6Remote battery voltage sense failure
- 7Remote battery voltage sense failure
- 8Remote battery voltage sense failure (connection lost)
- 11Battery high ripple voltage
- 17Controller overheated despite reduced output current
- 20Maximum Bulk-time exceeded
- 22Internal temperature sensor failure
- 23Internal temperature sensor failure
- 27Charger short circuit
- 29Overcharge protection
- 33PV overvoltage
- 34PV overcurrent
- 35PV over power
- 41Inverter shutdown (panel isolation resistance too low)
- 42Inverter shutdown (ground current too high >30mA)
- 43Inverter shutdown (ground fault)
- 50Inverter overload, inverter peak current
- 51Inverter temperature too high
- 52Inverter peak current
- 53Inverter output voltage
- 54Inverter output voltage
- 55Inverter self test failed
- 56Inverter self test failed
- 57Inverter AC voltage on output
- 58Inverter self test failed
- 59AC-IN1 relay test fault
- 65Communication warning
- 66Incompatible device
- 67BMS Connection lost
- 69Network misconfigured
- 70Network misconfigured
- 71Network misconfigured
- 72Phase rotation
- 73Multiple AC inputs
- 74Too many units in parallel
- 75Network misconfigured
- 76Network incomplete
- 77Settings sync disabled
- 116Calibration data lost
- 117Incompatible firmware
- 119Settings data lost
- 121Tester fail
- 200Internal DC voltage error
- 201Internal DC voltage error
- 202Internal GFCI sensor error
- 203Internal supply voltage error
- 204Internal supply voltage error
- 212Internal supply voltage error
- 215Internal supply voltage error
Victron SmartSolar MPPT (9)
- 1Battery temperature too high
- 18Solar charger over-current
- 21Current sensor issue
- 26Terminal overheated
- 28Power stage issue
- 38PV Input shutdown
- 39PV Input shutdown
- 40PV Input failed to shutdown
- 80-88PV Input shutdown series
Zamp (7)
- b01Battery Disconnected - controller cannot detect a battery bank
- b02Battery Reverse Connection - battery wires reversed
- b03Battery Over Voltage - input to battery terminals exceeds 17.5 V
- b04Battery Over Temperature - battery core over 65 C (149 F)
- p01Solar Panel Reverse Connection
- p02Solar Panel Over Voltage - greater than 26.5 V
- oTpController Over Temperature Protection - controller over 65 C (149 F) while charging