Error codes › Electrical (12V / 120V / Converter / Inverter) › Lithionics › Cell Temp High/Low

Lithionics error code Cell Temp High/Low

WarningElectrical (12V / 120V / Converter / Inverter)Verified against the manufacturer's manual

App status code: internal cell temperature is outside the operating limits, so charge or discharge current is disabled until it returns within limits. Limits differ for charging and discharging (GTX12V320A: charge 32~131 degF / 0~55 degC, discharge -4~131 degF / -20~55 degC; GTX12V310A RevA: 0-60 degC charge, -20~60 degC discharge).

What to check, and in what order, is in the app. A step-by-step flow walks this code with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Electrical (12V / 120V / Converter / Inverter) error codes · Look up another code