Girard error code STEP MODE NOT FUNCTIONING

WarningAwnings (Patio, Window, Slide Topper)Verified against the manufacturer's manual

The awning runs fully on a single press (Continuous mode) when Step mode is wanted (awning moves only while the button is held, stops on release). On the Girard Solar Station system the mode is toggled by holding IN + OUT together for five (5) seconds (the motor jogs twice); the Solar Station light flashes once to confirm Step mode. There is no STOP+RIGHT 6-second combo and no green controller LED.

What to check, and in what order, is in the app. The flow Girard GG750 Solar Station awning - STEP MODE NOT FUNCTIONING walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Awnings (Patio, Window, Slide Topper) error codes · Look up another code