Error codes › Slideout Rooms
Slideout Rooms error codes
53 codes from 4 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Lippert (10)
- 1 Red FlashParking brake (if applicable) is not set OR ground signal is lost at parking brake receptacle
- 7 Red FlashesStops have not been set, stops were cleared, or stops were improperly set
- 1Left motor fault - the GREEN LED blinks once (Basic Fault reporting mode), then the RED LED blinks ONCE.…
- 2Right motor fault - the GREEN LED blinks once (Basic Fault reporting mode), then the RED LED blinks TWICE.…
- 1F-1GPark Brake Not Set
- 1F-2GLow Voltage (< 10.5V)
- 1F-4GMotor 1 Fault
- 2F-4GMotor 2 Fault
- 1F-6GHigh Voltage (>= 17V)
- 1F-7GStops Not Programmed
Lippert (Schwintek In-Wall) (7)
- 2Battery Drop Out — Battery sagged below ~6V DC during a slide cycle, or there's a short in the slide-switch…
- 3Low Battery — Battery voltage was already below 8V DC at the start of the slide cycle.
- 4High Battery — Voltage at the controller is above 18V DC — overvoltage from converter, charging system, or…
- 5Excessive Motor Current — Motor is drawing too much amperage — usually because one side of the slide is…
- 6Motor Short Circuit - the motor itself or the wiring to it has shorted out. Note: over-current and…
- 8Missing Hall Effect (encoder) signal — The encoder (Hall effect sensor) isn't sending a signal back to the…
- 9Hall Power Short To Ground - the Hall-effect (encoder) power line has shorted to ground. Usually a wiring…
Lippert SlimRack Plus (30)
- G1/R1Motor 1 fault — Problem with motor 1 circuit
- G1/R2Motor 2 fault — Problem with motor 2 circuit
- G1/R3Battery fault — Problem with detected battery power
- G1/R4Parking brake fault - Parking brake not engaged
- G1/R5Switch power fault — Problem with the switch circuit
- G2/R1DTC_MOTOR_OUTPUT_1_SHORT_TO_GND — One motor 1 output is shorted to ground
- G2/R2DTC_MOTOR_OUTPUT_2_SHORT_TO_GND — One motor 2 output is shorted to ground
- G2/R3DTC_MOTOR_OUTPUT_1_SHORT — Motor 1 outputs shorted together (cross-short)
- G2/R4DTC_MOTOR_OUTPUT_2_SHORT — Motor 2 outputs shorted together
- G2/R5DTC_MOTOR_OUTPUT_1_OPEN — One motor 1 output is open
- G2/R6DTC_MOTOR_OUTPUT_2_OPEN — One motor 2 output is open
- G2/R7DTC_BATTERY_DROPOUT — Battery dropped out / short-to-battery introduced after movement began
- G2/R8DTC_OPERATING_VOLTAGE_DROPOUT - Detected low battery voltage during actuation
- G2/R9DTC_BATTERY_VOLTAGE_HIGH — Detected high battery voltage (>16 V)
- G2/R10DTC_PARK_BRAKE_SWITCH_FAULT — Parking brake not engaged when movement attempted
- G2/R11DTC_MOTOR_OUTPUT_1_OPEN_B — Motor 1 output became open after startup
- G2/R12DTC_MOTOR_OUTPUT_2_OPEN_B — Motor 2 output became open after startup
- G2/R13DTC_MOTOR_OUTPUT_1_SHORT_TO_BATT — Motor 1 output shorted to battery (or motor driver failed closed)
- G2/R14DTC_MOTOR_OUTPUT_2_SHORT_TO_BATT — Motor 2 output shorted to battery (or motor driver failed closed)
- G2/R15DTC_MOTOR_OUTPUT_1_SHORT_TO_BATT_B — Motor 1 short-to-battery after motor started moving
- G2/R16DTC_MOTOR_OUTPUT_2_SHORT_TO_BATT_B — Motor 2 short-to-battery after motor started moving
- G2/R17DTC_MOTOR_OUTPUT_1_OVER_CURRENT — High current on motor 1 output (Electronic Override mode only)
- G2/R18DTC_MOTOR_OUTPUT_2_OVER_CURRENT — High current on motor 2 output (Electronic Override mode only)
- G2/R19DTC_FUSE_1_OPEN — On-board self-resetting fuse for motor 1 is open
- G2/R20DTC_FUSE_2_OPEN — On-board self-resetting fuse for motor 2 is open
- G2/R23Internal controller failure (#1) - Internal controller failure
- G2/R24Internal controller failure (#2) - Internal controller failure
- G2/R25DTC_BATTERY_VOLTAGE_LOW — Battery voltage below 9 V
- G2/R26DTC_SWITCH_PWR_SHORT_TO_GROUND - Switch power output shorted to ground
- G2/R27Synchronization issue — Slide rails are out of sync
Power Gear SlimRack (1510000199) (6)
- 1G/2R touchpadTouchpad: 1 green LED + 2 red LEDs flashing = Motor 1, Fault Code 2 'System fault' (Minor) - obstruction…
- 1G/4R touchpadTouchpad: 1 green LED + 4 red LEDs flashing — rail/motor 1 fault
- 1G/6R touchpadTouchpad: 1 green LED + 6 red LEDs flashing = Motor 1, Fault Code 6 'Excessive battery voltage' (Minor) …
- 2G/4R touchpadTouchpad: 2 green LEDs + 4 red LEDs flashing — rail/motor 2 fault
- Park brakeTouchpad: "Engage park brake" LED is flashing
- Low voltageTouchpad: "Low voltage" LED is flashing — DC supply below operating threshold