Error codes › LP / Propane System › MTI Safe-T-Alert 85 Series › Alternating red/green LED + 1 beep every 15-30 s (Gas LED off)

MTI Safe-T-Alert 85 Series error code Alternating red/green LED + 1 beep every 15-30 s (Gas LED off)

FaultLP / Propane SystemVerified against the manufacturer's manual

MALFUNCTION / SERVICE SIGNAL (85 series): an internal fault was detected - the Gas LED stays off, the Operational/CO LED alternates red/green and the alarm sounds once at an interval. The manual prints THREE different intervals for this one signal: the prose says once every 15 seconds, the signal table says BEEP EVERY 30 SECONDS, and the troubleshooting chart says beeps every 15 seconds. Treat ANY alternating red/green with a periodic single beep as this signal. The alarm operates normally down to 7 VDC; do not operate it below 7 VDC.

What to check, and in what order, is in the app. The flow MTI Safe-T-Alert 20/25/30/40/45/62/65/85 series - alarm and LED signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All LP / Propane System error codes · Look up another code