Error codes › LP / Propane System › MTI Safe-T-Alert 25 Series › Red-red-green-green flashing LED + beep every 25-30 s
MTI Safe-T-Alert 25 Series error code Red-red-green-green flashing LED + beep every 25-30 s
END OF LIFE (25 series): the sensor's 5-year service life has ended and the alarm must be replaced. TEST/RESET resets the EOL signal for 72 hours (3 days), for a total of up to 30 days; after that it cannot be reset.
What to check, and in what order, is in the app. The flow MTI Safe-T-Alert 20/25/30/40/45/62/65/85 series - alarm and LED signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Safe-T-Alert 25 Series Combination Carbon Monoxide and Gas Alarm User's Manual (25RV052023, 2023)MTI Industries, Inc. (Safe-T-Alert)
Related codes
- Flashing green LED, no sound (warm-up, about 10 min)Warm-up (25 series): each time the unit is first powered up the CO…
- Steady red CO LED + 4 beeps, 5 s silence (repeating)CO ALARM (25 series): the red CO LED flashes and the alarm sounds 4…
- Flashing red Gas LED + constant beepingPROPANE GAS ALARM (25 series): the red Gas LED flashes and the alarm…
- Alternating red/green LED + 1 beep every 15-30 s (Gas LED off)MALFUNCTION / SERVICE SIGNAL (25 series): an internal fault was…
- Green operational LED off (dark, no sound)No power / no operation (25 series). Troubleshooting causes: bad wire…