Error codes › RVMP Flex Power
RVMP Flex Power error codes
9 codes from 1 manufacturer, each with its meaning and the document it comes from. Open a code for the details, or search every system.
RVMP Flex Power (9)
- Low Oil (light on)The oil-level float switch has tripped and is inhibiting start: oil level is low, or the float/sensor is…
- Low Oil (light off, but generator won't start)Low Oil indicator is unlit AND the generator will not start. The sensor circuit relies on spark energy to…
- Overload (light on, Ready off)Inverter reports electrical overload condition. During normal operation the Overload light is OFF and the…
- No Ready light, no 120V outputEngine starts and runs but the inverter never produces clean AC output. Digital display shows 0 V output…
- No throttle response (idle or load)Engine runs but the throttle stepper motor never moves — no small movements at idle, no adjustments when load…
- Rough running or 'hunting' (no load)Engine RPMs swing rapidly up and down when the AC breaker is OFF (no electrical load). Most common cause is a…
- Runs a few minutes then shuts downGenerator starts and runs normally for 5-10 minutes then shuts down. With no electrical load, the cause is…
- Completely dead (no lights at all)No response on START button, no lights on the control panel. Most common causes: dead battery, reversed…
- Intermittent start (starts sometimes, not others)Inconsistent starting behavior. Top three causes: marginal battery voltage/CCA, oil shifting in the pan on…