Error codes › Diesel Air Heaters › Eberspacher EasyStart Pro control unit (controller display - not a heater code) › Air Ducting or Outlet
Eberspacher EasyStart Pro control unit (controller display - not a heater code) error code Air Ducting or Outlet
AIR heaters only: air outlet temperature in the heater too high (heater message). Airtronic 2 class 5 = overheating P000115 (012, sensor >125 degC software threshold) and P000116 (017, >130 degC hardware threshold).
What to check, and in what order, is in the app. The flow Eberspacher EasyStart Pro - what the controller is showing (control-unit codes 1-9 + heater messages) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Eberspacher EasyStart Pro Operating Instructions 22.1000.35.2204.0A (EN, 07.2021)Eberspacher Climate Control Systems GmbH
- Eberspacher Repair instructions Airtronic 2 - S2 D2L Fault Codes and Diagnosis 25.2720.95.2682.0D (02.2020)Eberspacher (via butlertechnik)
Related codes
- UndervoltageUndervoltage at the heater control box without interruption for at…
- OvervoltageOvervoltage at the heater control box without interruption for at…
- Fuel Supply or PumpFault in the fuel supply or the metering pump (heater message).…
- Water Circuit or PumpWATER heaters only (Hydronic S3): water temperature in the heater too…
- Overheat. Heater locked.Overheating detected and the heater is interlocked (locked out) for…
- Restricted OperationEmergency running: a heater fault exists but restricted operation…
- Heater ON for 10 Min.Maintenance prompt, not a fault: after four months without operation…
- 1Ext. Temp. Sensor defective - the external temperature sensor…