Error codes › LP / Propane System › MTI Safe-T-Alert 65 Series › Alternating red/green LED + 1 beep every 15-30 s
MTI Safe-T-Alert 65 Series error code Alternating red/green LED + 1 beep every 15-30 s
MALFUNCTION / SERVICE SIGNAL (65 series CO alarm): the Operational/CO LED alternates red/green and the alarm sounds once at an interval. The manual prints different intervals for this one signal: prose says once every 15 seconds, the signal table BEEP EVERY 25 SECONDS, the troubleshooting chart beeps every 25 seconds. Treat any alternating red/green with a periodic single beep as this signal. The alarm operates normally down to 7 VDC.
What to check, and in what order, is in the app. The flow MTI Safe-T-Alert 20/25/30/40/45/62/65/85 series - alarm and LED signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Safe-T-Alert 65 Series Carbon Monoxide Alarm User's Manual with relay / interconnect wiring (65RV120810-6, 2011)MTI Industries, Inc. (Safe-T-Alert)
Related codes
- Steady green LED, no soundNormal operation (65 series CO detector): powered and monitoring; no…
- Flashing green LED, no sound (warm-up, about 10 min)Warm-up (65 series CO detector): on power-up the CO sensor requires a…
- Steady red CO LED + 4 beeps, 5 s silence (repeating)CO ALARM (65 series CO alarm): the red CO LED flashes and the alarm…
- Red-red-green-green flashing LED + beep every 25-30 sEND OF LIFE (65 series CO detector): the CO sensor's 5-year service…
- 1 to 4 chirps + matching green/red blinks after a short Test/Reset press (peak CO memory)PEAK LEVEL MEMORY readout (65 series CO detector): pressing…
- Green operational LED off (dark, no sound)No power / no operation (65 series CO alarm): wire connection…