Redarc error code 6 flash
Input over voltage from vehicle or solar input, OR the solar panel is connected in reverse polarity
What to check, and in what order, is in the app. The flow REDARC BCDC Classic — Status LED Lookup walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- REDARC BCDC Core In-Vehicle Battery Charger ManualREDARC
- REDARC North America - BCDC Classic Flashing Fault Codes (BCDC1225D/1240D/1250D)
Related codes
- 2 flashUnit below minimum operating temperature (low temp)
- 3 flashUnit above maximum operating temperature (high temp)
- 4 flashOutput Battery fault - voltage too high
- 5 flashInput (battery) voltage below 9 V (or solar below 9 V)
- All 8 flashPoor or no earth connection on the BCDC black wire