Error codes › DC-DC Chargers (Alternator → House Battery)
DC-DC Chargers (Alternator → House Battery) error codes
45 codes from 4 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Redarc (7)
- 1 flashInternal Hardware Fault
- 2 flashUnit below minimum operating temperature (low temp)
- 3 flashUnit above maximum operating temperature (high temp)
- 4 flashOutput Battery fault - voltage too high
- 5 flashInput (battery) voltage below 9 V (or solar below 9 V)
- 6 flashInput over voltage from vehicle or solar input, OR the solar panel is connected in reverse polarity
- All 8 flashPoor or no earth connection on the BCDC black wire
Renogy DCC50S/DCC30S (5)
- Service battery LED green (solid)Battery FULL - the service battery is fully charged. Normal.
- Service battery LED yellow (solid)Battery voltage NORMAL - the service battery is in its normal voltage range.
- Service battery LED red (solid)Battery UNDERVOLTAGE - the service battery is low. The indicator turns red at the 12.0V under-voltage warning…
- Service battery LED red slow-flashingBattery OVER-DISCHARGED - the service battery has dropped below the over-discharge point.
- Service battery LED red fast-flashingBattery OVER-VOLTAGE or OVER-TEMPERATURE - charge voltage is too high or the battery temperature is out of…
Sterling Power (14)
- Battery Type YellowBattery type selected: Open lead-acid (info-only LED on top panel; confirms chemistry-select setting)
- Battery Type GreenBattery type selected: manual's item-14 legend reads Gel/sealed lead-acid (info-only LED); NOTE -- the same…
- Battery Type RedBattery type selected: AGM (info-only LED; confirms chemistry-select setting)
- Alt Over Temp YellowAlternator over-temperature (manual gives conflicting figures: LED-meaning table says 90 °C, installation…
- Constant Current GreenBulk (high charge) cycle active — output current at maximum rated for the unit
- Timer On YellowAbsorption (timer) cycle active — battery has reached 13.9–14.0 V, timed absorption running
- Float GreenFloat mode — high-charge cycle complete; aux battery holding at float voltage
- Battery Input Over Volts RedVehicle alternator output excessive — boost SHUT OFF (alternator regulator failure / runaway). STOP-ENGINE…
- Battery Input Low Volts YellowLow voltage at vehicle (start-battery) side — info-only; possible failing alternator or worn start battery
- Battery Output Over Volts RedAuxiliary bank over-voltage — boost SHUT OFF. Either internal BB unit failure OR a competing charger on the…
- Battery Output Low Volts YellowAuxiliary bank low voltage — BB unit can't keep up with house load OR has failed
- Battery Output Over Temp RedAuxiliary battery temperature sensor reads > 50 °C — output TRIPPED. MANUAL RESET required after fault cause…
- Heatsink Over Temp YellowBB unit heatsink over-temperature — manual gives conflicting figures (LED-meaning table: 75 °C; spec table…
- Device Failure RedInternal device failure — no field-repair available
Victron Orion XS DC-DC (19)
- Error 1Battery temperature too high
- Error 2Battery voltage too high
- Error 17Controller overheated despite reduced output current
- Error 21Current sensor issue
- Error 26Terminal overheated
- Error 27Charger short circuit
- Error 28Power stage issue
- Error 33Input voltage too high
- Error 67BMS connection lost
- Error 116Calibration data lost
- Error 117Incompatible firmware
- Error 119Settings data lost
- Error 120Internal supply voltage error
- Error 122History data corrupted
- Warning 150Battery temperature too high
- Warning 151Battery temperature too low
- Warning 160Current derate due to controller high temperature
- Warning 161Short circuit detected
- Warning 162Power stage issue