Error codes › Air Conditioning (Rooftop)
Air Conditioning (Rooftop) error codes
112 codes from 11 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Coleman Mach (Mechanical) (4)
- NO OPERATIONAC doesn't respond to thermostat. Usually 120V supply or breaker.
- FAN NO COMPFan operates but compressor doesn't start. Usually capacitor or thermal overload.
- COMP NO FANCompressor operates but fan motor not spinning. Usually fan capacitor or motor.
- POOR COOLINGBoth fan and compressor run but cooling is weak. Usually airflow restriction, dirty coil, or low refrigerant.
Coleman-Mach (2)
- HP LOCKOUTR-410A heat pump high-pressure lockout circuit tripped. Compressor stays locked until 115 VAC supply is…
- HP REVERSINGHeat pump cools when heat is called. Reversing valve solenoid or wiring fault — slide is not reversing…
Coleman-Mach Everest VS-18 (9)
- E1Room Temperature Sensor Fault - the room temperature sensor inside the ACTH3 wall thermostat is damaged or…
- E2Indoor Coil Temperature Sensor Fault - the ICT sensor on the evaporator coil is damaged or has poor contact
- E3External Environment Temperature Sensor Fault - the ambient outdoor-air sensor is damaged or has poor contact
- E4Outdoor Coil Temperature Sensor Fault - the OCT sensor on the condenser coil is damaged or has poor contact
- E5Compressor Discharge Temperature Sensor Fault - the discharge sensor at the compressor outlet is damaged or…
- E7Compressor Discharge Temperature Exceeded 110 degC (230 degF) - outdoor coil is blocked or refrigerant is…
- E8Indoor Coil Temperature Below -12 degC (10.4 degF) - indoor coil is blocked; recovery threshold +7 degC (44.6…
- E9Communication Fault Between the ACTH3 Thermostat and the Main Control Board - interface circuit is damaged…
- dECompressor Driver Fault - check wires connecting to the compressor driver or the compressor; if no loose…
Dometic CCC2 (9)
- E1Loss of communication between the CCC2 thermostat and one or more control boards. The affected control board…
- E2Open or out-of-range indoor temperature sensor. Heat, cool, and dehumidify lock out on the affected zone…
- E3Shorted indoor temperature sensor. Heat, cool, and dehumidify lock out on the affected zone; manual fan still…
- E4Open or out-of-range outdoor temperature sensor (heat-pump models). Heat-pump and dehumidify lock out; A/C…
- E5Open or out-of-range freeze sensor. A/C and dehumidify lock out; heat pump, furnace, heat strip, and fan…
- E6Open-circuit humidity sensor (fitted only on select multi-zone CCC2 systems). Air conditioner and…
- E7Loss of 120 VAC power. All 120 VAC relays switch off after a 120-second delay (which allows for automatic…
- E8Invalid zone configuration - the heat pump AND heat strip DIP switches are both set ON in one zone (an…
- E9Invalid zone configuration - the dehumidifier DIP switch and either the heat pump or heat strip DIP switch…
Dometic FreshJet 7 48V (21)
- P1Under-voltage protection: input voltage below 41 V +-1 V. Clears when input voltage rises above 45 V; the…
- P2Over-current protection: running current exceeds the limit value. The system recovers automatically and…
- P3Over-voltage protection: input voltage over 61 V +1 V. Clears when input voltage falls below 57 V…
- P4Discharge over-temperature protection: compressor exhaust temperature above the shutdown protection value.…
- P5Cooling anti-freezing protection: indoor pipe (evaporator) temperature below the set value while cooling.…
- P6Cooling overheat protection: outdoor pipe (condenser) temperature beyond its set value while cooling. Clears…
- P7Heating overheat protection: indoor pipe temperature above the set value while heating. Clears when the…
- P8Outdoor temperature too high/low protection: outdoor temperature below 32 degF in cooling, or above 90 degF…
- E0Indoor/outdoor communication fault: no indoor-outdoor communication, or outdoor power abnormal. Restarts…
- E1Room temperature sensor fault: indoor ambient temperature sensor short or open circuit. Restarts…
- E2Indoor coil temperature sensor fault: short or open circuit. Restarts automatically once the sensor is…
- E3Outdoor coil temperature sensor fault: short or open circuit. Restarts automatically once the sensor is…
- E6Indoor fan fault: indoor fan not running or speed abnormal. System recovers automatically; restarts after 3…
- E7Outdoor temperature sensor fault: outdoor ambient temperature sensor short or open circuit. Restarts…
- E8Discharge temperature sensor fault: outdoor exhaust temperature sensor short or open circuit. Restarts…
- E9Inverter drive/module fault: drive or module protection occurs 6 times in 30 min. Clears on power off /…
- EACurrent sensor fault: compressor current below 1 A for 30 s. System recovers automatically; restarts after 3…
- EEOutdoor EEPROM fault: cannot read EEPROM data. Documented clearance: re-flash the EEPROM, power off. (Dometic…
- ELLIN communication fault during self-check. Restarts automatically once LIN communication is restored.…
- EFOutdoor fan fault: outdoor DC fan motor not running or speed abnormal. System recovers automatically…
- ECCAN communication fault during self-check. Restarts automatically once CAN communication is restored.…
Dometic FreshJet FJX (19)
- P0Protection shutdown: over-temperature or over-current detected on the IPM (inverter power) module. (Dometic…
- P1Protection shutdown: supply under-voltage. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- P2Protection shutdown: unit AC over-current. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- P3Protection shutdown: supply over-voltage. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- P4Protection shutdown: compressor discharge tube overheat. (Dometic FreshJet Series 4/7 rooftop AC - models…
- P5Protection shutdown: evaporator coil protection tripped in cooling mode. (Dometic FreshJet Series 4/7 rooftop…
- P6Protection shutdown: condenser coil protection tripped in cooling mode. (Dometic FreshJet Series 4/7 rooftop…
- P7Protection shutdown: evaporator coil protection tripped in heating mode. (Dometic FreshJet Series 4/7 rooftop…
- P9Protection shutdown: compressor drive abnormal, or the compressor does not start. (Dometic FreshJet Series…
- E0Fault: communication failure. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH, FJX7333IHP…
- E1Fault: room (return air) temperature sensor. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- E2Fault: evaporator coil temperature sensor. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- E3Fault: condenser coil temperature sensor. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH…
- E7Fault: outdoor temperature sensor. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH, FJX7333IHP…
- E8Fault: compressor discharge tube temperature sensor. (Dometic FreshJet Series 4/7 rooftop AC - models…
- E9Fault: compressor drive or IPM (inverter power) module. (Dometic FreshJet Series 4/7 rooftop AC - models…
- EAFault: current sensor. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH, FJX7333IHP, FJX7337IHP…
- EEFault: outdoor unit EEPROM. (Dometic FreshJet Series 4/7 rooftop AC - models FJX4333EEH, FJX7333IHP…
- ELFault: LIN-BUS / CI-BUS communication failure between the unit and its control network. (Dometic FreshJet…
Furrion Chill Cube (8)
- Solid red LEDInternal control board fault
- E3Loss of communication between the thermostat and control box. System will shut down (both cooling and…
- E6Thermostat indoor temperature sensor out of order. System will shut down.
- loInsufficient low level of +12V power supply. System will shut down.
- E1Control box indoor temperature sensor out of order. System will shut down.
- E2Evaporator temperature sensor out of order. System will shut down.
- E4Condenser temperature sensor out of order. System will shut down.
- E5Outdoor temperature sensor out of order. System will shut down.
Furrion Chill Variable Speed Thermostat (2)
- E6Thermostat indoor temperature sensor out of order. System will shut down. Internal NTC temperature sensor in…
- loInsufficient low level of +12V power supply. System will shut down.
GE RVAC (10)
- -- or FCThermostat signal wire is unplugged or shorted (not communicating with main control)
- F1Indoor coil thermistor — unplugged sensor or temperature less than -22°F (-30°C)
- F2Indoor coil thermistor — shorted wires or temperature greater than 149°F (65°C)
- F3Outdoor coil thermistor — unplugged or temperature less than -22°F (-30°C)
- F4Outdoor coil thermistor — shorted or temperature greater than 149°F (65°C)
- F5Outdoor ambient temp sensor — unplugged or reading below -22°F (-30°C)
- F6Outdoor ambient temp sensor — shorted or reading above 149°F (65°C)
- F7Thermostat room sensor — unplugged or reading below -22°F (-30°C)
- F8Thermostat room sensor — shorted or reading above 149°F (65°C)
- Lo (flashing)Low voltage detection — 12 VDC dropped below 10.5 V. Thermostat switched to OFF mode. 'Lo' flashes while…
Gree (10)
- E6Communication failure between control board and display/thermostat (or indoor and outdoor on split-style).…
- E8High-temperature / overload protection. Often evaporator overheat or indoor motor protection trip.
- F0Refrigerant-shortage / blockage protection. Per the manual, the display shows F0 after the unit enters…
- F1Indoor ambient sensor open or short circuit.
- F2Indoor coil/evaporator sensor open or short circuit.
- F3Outdoor ambient sensor open or short circuit.
- F4Outdoor coil/condenser sensor open or short. On some units, discharge-related.
- H1Defrost cycle active (status — heat pump removing frost from outdoor coil). NOT a fault. Houghton displays…
- H3Compressor overload (thermal cutout tripped).
- PLSupply voltage below the controller's limit. Per the manual: 'If controller detects that system voltage lower…
RecPro RP-AC48V (Houghton AEOLUS) (18)
- E0Motherboard-to-display-board communication fault on the RP-AC48V-H2800/H3400 48 V units (indoor PCB cannot…
- E1Room (return-air) temperature sensor fault - sensor open or shorted.
- E2Indoor coil (evaporator) temperature sensor fault - sensor open or shorted.
- E3Indoor DC fan (evaporator blower) fault - no feedback/tach signal from the indoor blower motor.
- E5Poor performance / insufficient cooling or heating capacity (system efficiency below threshold).
- 0EOutdoor ambient temperature sensor fault - sensor open or shorted.
- 1EOutdoor coil (condenser) temperature sensor fault - sensor open or shorted.
- 2EOutdoor discharge (exhaust) temperature sensor fault - compressor discharge-line sensor open or shorted.
- 4EOutdoor DC fan (condenser fan) fault - no feedback/tach signal from the outdoor fan motor.
- 5EDC bus over-voltage protection - the 48 V supply exceeded the safe input window (45-60 V).
- 6EDC bus under-voltage protection - the 48 V supply dropped below the safe input window (45-60 V).
- 7ECompressor stall protection - the inverter detected the compressor failing to start/turn.
- 8ECompressor locked-rotor protection - the inverter detected a locked/seized compressor rotor.
- 9ECompressor phase-current protection (software) - measured phase current exceeded the firmware limit.
- AECompressor phase-current protection (hardware) - the drive hardware tripped on excessive phase current.
- bECommunication fault between the electric control board and the compressor (inverter) drive board.
- dFDefrost in progress - NORMAL heat-pump operation (not a fault). In heating, the outdoor coil periodically…
- LoLow-voltage warning - the 48 V supply is low (advisory, shown before the 6E under-voltage protection trip).