Error codes › Water Heater — Tankless › Furrion F2GWH (tankless) › E1

Furrion F2GWH (tankless) error code E1

FaultWater Heater — TanklessVerified against the manufacturer's manual

Ignition failure or accidental flame off during ignition - after two failed trials the control locks out. Most common causes: lack of gas, faulty igniter or igniter connections, wrong igniter-to-burner distance, dirt between igniter and burner, low gas inlet pressure.

What to check, and in what order, is in the app. The flow Furrion F2GWH tankless - error codes E0-E9, En, Fd and symptoms walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Water Heater — Tankless error codes · Look up another code