Error codes › LP / Propane System › MTI Safe-T-Alert 62 Series › 1 to 4 chirps + matching green/red blinks after a short Test/Reset press (peak CO memory)

MTI Safe-T-Alert 62 Series error code 1 to 4 chirps + matching green/red blinks after a short Test/Reset press (peak CO memory)

InformationLP / Propane SystemVerified against the manufacturer's manual

PEAK LEVEL MEMORY readout (62 series CO detector): pressing TEST/RESET for LESS than 1 second makes the alarm report the approximate CO level that last activated it: 1 chirp + 1 green blink = memory clear; 2 chirps + 2 red blinks = below 100 ppm; 3 chirps + 3 red blinks = below 200 ppm; 4 chirps + 4 red blinks = above 200 ppm. Brief exposures that would not activate the alarm are not recorded.

What to check, and in what order, is in the app. The flow MTI Safe-T-Alert 20/25/30/40/45/62/65/85 series - alarm and LED signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All LP / Propane System error codes · Look up another code