MTI Safe-T-Alert 45 Series error code Alternating red/green LED + 1 beep every 15-30 s (Gas LED off)
MALFUNCTION / SERVICE SIGNAL (45 series): an internal fault was detected - the Gas LED stays off, the Operational/CO LED alternates red/green and the alarm sounds once at an interval. The manual prints THREE different intervals for this one signal: the prose says once every 15 seconds, the signal table says BEEP EVERY 30 SECONDS, and the troubleshooting chart says beeps every 15 seconds. Treat ANY alternating red/green with a periodic single beep as this signal. The alarm operates normally down to 7 VDC; do not operate it below 7 VDC.
What to check, and in what order, is in the app. The flow MTI Safe-T-Alert 20/25/30/40/45/62/65/85 series - alarm and LED signal decoder walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Safe-T-Alert Models 45-741 & 45-742 Combination Carbon Monoxide and Gas Alarm User's Manual (45RV052017-1, 2017)MTI Industries, Inc. (Safe-T-Alert)
Related codes
- Steady green LED, no soundNormal operation (45 series combination CO/propane alarm): both…
- Flashing green LED, no sound (warm-up, about 10 min)Warm-up (45 series): each time the unit is first powered up the CO…
- Steady red CO LED + 4 beeps, 5 s silence (repeating)CO ALARM (45 series): the red CO LED flashes and the alarm sounds 4…
- Flashing red Gas LED + constant beepingPROPANE GAS ALARM (45 series): the red Gas LED flashes and the alarm…
- Red-red-green-green flashing LED + beep every 25-30 sEND OF LIFE (45 series): the sensor's 5-year service life has ended…
- Green operational LED off (dark, no sound)No power / no operation (45 series). Troubleshooting causes: bad wire…