Truma Combi error code 10 (PCB flash code ssss, lsls)
Plausibility of Combustion Air Sensor. Combustion Air Sensor outside of tolerance range - sensor or harness.
What to check, and in what order, is in the app. The flow Truma Combi — Ignition / Electrode Diagnostics (Code 0088) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.
Start free trial 14 days free, no card neededDocumented in
- Truma Combi Service HandbookTruma
- Truma Combi Service Handbook (TrumaCorp, 20 pp; technician training handbook with Common Error Codes table and per-code Further Details sections) (rv-tech-resources/58-truma-combi-hydronic/Truma-Combi-Service-Handbook_TrumaCorp_20pp.pdf)
- Truma Combi Diagnostics Catalogue (canonical 57-code reference, external PDF at leisureshopdirect.com/pdf/370196265.pdf)
- Truma Combi 4 / 6 / Plus / E / D Technician Service Diagnostic Reference (rv-tech-resources/58-truma-combi-hydronic/Truma_Combi_4_6_Plus_E_D_Technician_Service_Diagnostic_Reference.md)
Related codes
- 4 (PCB flash code ssss, slss)Current for combustion air motor too high. Combustion air motor…
- 5 (PCB flash code ssss, slsl)Current for combustion air motor too low. Combustion air motor, cable…
- 6 (PCB flash code ssss, slls)Current for combustion air motor too high. Combustion air motor…
- 8 (PCB flash code ssss, lsss)Recheck flash code. Electronic fault - Failure in PCB.
- W 18 HWarm air outlets blocked / circulated air intake blocked. Yellow…
- 0020Plausibility of NTC Water Temperature Sensor. Water Temperature…
- W 21 HPlausibility of NTC Room Temperature Sensor. Room Temperature Sensor…
- W 22 HPlausibility of NTC Air Temperature Sensor. Air Temperature Sensor…