Error codes › Electrical (12V / 120V / Converter / Inverter) › Schneider Conext › W57

Schneider Conext error code W57

WarningElectrical (12V / 120V / Converter / Inverter)Verified against the manufacturer's manual

FET1 over-temperature: internal temperature is over 85 degC (185 degF). Causes incl. high AC input voltage while charging, too-large a load too long while inverting, high ambient, failed cooling fan, or blocked airflow.

What to check, and in what order, is in the app. The flow Coach Electrical — entry diagnostic (converters / inverters / solar / monitors) walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Electrical (12V / 120V / Converter / Inverter) error codes · Look up another code