Schneider Conext error code F57
FET1 over-temperature shutdown: internal temperature is over 105 degC; the fault clears when temperature drops to 75 degC. Causes incl. high AC input voltage while charging, too-large a load too long while inverting, high ambient, failed cooling fan, blocked airflow, or charge rate too high.