Error codes › Diesel Air Heaters › Webasto SmarTemp Control 3.0 / 4.0 (controller display - not a heater code) › Low voltage warning (LED + message)

Webasto SmarTemp Control 3.0 / 4.0 (controller display - not a heater code) error code Low voltage warning (LED + message)

WarningDiesel Air HeatersVerified against the manufacturer's manual

SmarTemp's own Low Voltage Disconnect (LVD): supply at or below the LVD setting. The warning (status LED and message) appears after 8 minutes of low voltage and stays 2 minutes, then the SmarTemp switches the heater off. At or below the setting + 0.1 V the heater will not start. Default setting 11.4 V (12 V) / 24.2 V (24 V); adjustable 11-12.5 V / 21-25.5 V; can be disabled (disables only the SmarTemp's internal LVD).

What to check, and in what order, is in the app. The flow Webasto SmarTemp Control 3.0 / 4.0 - fault display, lock-out, low-voltage disconnect walks this code step by step with the pass/fail measurements, wiring schematics and procedures that go with it, and it works offline in the bay.

Start free trial 14 days free, no card needed

Documented in

Related codes

All Diesel Air Heaters error codes · Look up another code