Error codes › Cooking Appliances (Range / Cooktop / Microwave / Induction)
Cooking Appliances (Range / Cooktop / Microwave / Induction) error codes
20 codes from 5 manufacturers, each with its meaning and the document it comes from. Open a code for the details, or search every system.
Furrion FIH1ZEA / Greystone BW-K35 induction (1)
- E0No-pan / incompatible-cookware detected - Greystone BW-K35 E0. On Furrion FIH1ZEA the no-cookware code is 'U'…
Furrion FIH1ZEA Induction (6)
- E2Voltage LOW — supply voltage below operating range (different from Suburban!)
- E3Supplied voltage TOO HIGH - input voltage above the acceptable range (mirror of E2 = voltage too low). On the…
- E7Overheat protection (the FIH1ZEA manual groups E7/E8/E9/EE): the cooktop internal heat sensor detected high…
- E8An internal fault has been detected (the FIH1ZEA manual groups E7/E8/E9/EE together under this single row…
- E9An internal fault has been detected (the FIH1ZEA manual groups E7/E8/E9/EE together under this single row…
- EEAn internal fault has been detected (the FIH1ZEA manual groups E7/E8/E9/EE together under this single row…
Greystone BW-K35 Induction (1)
- E2NTC temperature-sensor fault (NTC1 IGBT / NTC2 heating-center open or shorted) on the Greystone BW-K35…
Suburban Induction Cooktop (1)
- E2Voltage HIGH — supply voltage above operating range (typical 120 VAC over-voltage)
True Induction (TI-2B/S2F2 family) (11)
- E1Meaning differs by model generation. TI-2C (current): internal circuit error - contact the manufacturer.…
- E2Meaning differs by model generation. TI-2B (2023) and S2F2: supplied voltage over 145 V. TI-2C (current)…
- E5TI-2C (current): top-plate sensor open/short circuit. S2F2: temperature sensor defective or short circuit …
- E6TI-2B (2023) and S2F2: cooking temperature exceeded 450 degF in TEMP mode - after ~3 minutes in standby the…
- E7TI-2B (2023) and S2F2: ventilation blocked - heat cannot exhaust and the internal device overheats; keep 2-4…
- E9Sensor-under-glass temperature too low after ~6 minutes of operation - possible large cold pot at low power…
- EEBuilt-in 150-minute safety timer expired - normal auto-shutoff (TI-2B 2023 and S2F2 display 'EE'; the TI-2C's…
- E3Meaning differs by model generation. TI-2C (current): supplied voltage to the cooktop is too HIGH - the code…
- E4Meaning differs by model generation. TI-2C (current): supplied voltage to the cooktop is too LOW - the code…
- --No cookware found, incompatible (non-ferromagnetic) cookware, or improper placement on the cooking zone.…
- E8Control panel connection loose / power sharing invalid - internal harness or board-to-panel connection fault…